Technical Summary — At a Glance
| Specification |
Detail |
| Product code |
2000-1.5KPA |
| Dial range |
0–1.5 kPa (0–1500 Pa) |
| Standard accuracy |
±2% full scale at 21.1°C (±30 Pa) |
| Power / display |
No external power; 4″ (101.6 mm) analogue dial |
| Connections |
1/8″ female NPT; duplicate high / low ports at side and rear |
Overview
Product images illustrate the series. Use the stated model code, pressure range and units when ordering.
The 2000-1.5KPA is a 0–1.5 kPa (0–1500 Pa) Magnehelic differential pressure gauge for local indication of filter pressure drop, fan pressure and duct or room pressure in AHU / HVAC systems. Its magnetic movement provides a dial reading without an electrical supply.
Specifications
| Specification |
Detail |
| Manufacturer / family |
Dwyer / Series 2000 Magnehelic |
| Service |
Air and compatible non-combustible gases; check wetted-material compatibility with the manufacturer |
| Housing / cover |
Die-cast aluminium case and bezel; acrylic cover (standard construction) |
| Enclosure |
IP67 (manufacturer’s standard Series 2000 rating) |
| Temperature limits |
−6.67 to +60°C (standard version) |
| Total pressure rating |
−20 inHg to 15 psig (−0.677 to +1.034 bar); separate from the dial measurement range |
| Mounting / weight |
Vertical diaphragm; surface or flush panel mounting; standard weight 510 g |
| Manufacturer’s standard accessory pack |
Two 1/8″ NPT plugs, two pipe-thread-to-tubing adapters, three flush-mount adapters with screws |
| Optional features |
HA accuracy, MP / HP pressure versions, special diaphragms, low-temperature versions, calibration certificates and application kits require separate confirmation |
Downloads
Application and optional-version documents
Use these only where the corresponding kit or option is specified. Their inclusion here does not mean those items are supplied with this gauge.
View the manufacturer’s Series 2000 resources and options.
Installation & Suitability
Check the required scale against the operating duty and, for filters, the specified final pressure drop. Mount vertically away from excessive vibration. Follow the A-27 dimensional drawing before making panel holes; standard and MP / HP mounting arrangements differ.
For differential measurement connect the higher pressure to “+” and lower pressure to “−”, and seal unused duplicate ports. Zero after installation with both sensing sides open to atmosphere. Keep the rear relief path clear. The relief plug does not extend the permitted system-pressure rating.
Verify gas, temperature and system-pressure suitability before use. Special gas service, repeated pressure cycling or a different mounting orientation requires manufacturer advice. These Pa / kPa scales indicate pressure; air velocity requires a suitable pitot arrangement and conversion.
FAQs
Is 1.5 kPa the maximum system pressure?
No. It is the top of this dial’s differential measurement range. The total-pressure rating is a separate limit shown above.
Does it need power or provide alarm switching?
The standard gauge needs no power for its reading and provides local indication. If alarm contacts are required, select a suitable switch/gauge; do not assume an indication-only gauge has them.
Is a calibration certificate or high-accuracy version included?
These are separately specified options. Standard accuracy for this range is ±2% of full scale, rather than a percentage of the current reading. Confirm any certificate requirement when ordering.
Compatible Accessories & Related Products
CPVC05 clear PVC manometer tubing — 3/16″ ID × 5/16″ OD, sold per metre is a separate item. Check adapter fit and media / temperature suitability. Follow the manual’s tubing recommendations for permanent installations.
Compare other Magnehelic ranges: 2000-250PA · 12-102097-00 · 2000-1000PA · 2000-100PA · 2000-125PA. Different ranges require selection; they are not automatic replacements.
Browse gauges and accessories. Ask us about filter-monitoring and mounting kits for your application.